1
/
of
3
Zoll
Zoll AED Pro
Zoll AED Pro
Regular price
$3,378.00 USD
Regular price
Sale price
$3,378.00 USD
Unit price
/
per
Couldn't load pickup availability



-
Description
-
Specifications
Zoll AED Pro Features
The Zoll AED Pro is equipped with advanced features to support both Basic Life Support (BLS) and Advanced Life Support (ALS). Its high-resolution LCD display enables responders to view the patient’s ECG clearly, using a 3-lead monitoring cable. The device is designed for durability with rubber over-molds, making it suitable for harsh environments. It also uses the unique one-piece CPR-D padz for straightforward pad placement.
- High-Quality Display: Provides clear visualization of the patient's ECG.
- ECG Monitoring: Utilizes a 3-lead cable for real-time heart activity monitoring.
- Manual Override: Offers options for ALS professionals to manually manage defibrillation.
- Data Storage and Transfer: Internal memory with IrDA or USB for easy data transfer.
- CPR Feedback: Gives real-time feedback on chest compressions through the CPR-D padz.
Zoll AED Pro Specifications
Dimensions
- Height: 3” (7.6 cm)
- Width: 9.2” (24.1 cm)
- Depth: 9.4” (23.9 cm)
- Weight: 6.5 lbs (2.9 kg)
Defibrillator
- Waveform: ZOLL Rectilinear Biphasic waveform.
- Energy: 50, 70, 85 (pediatric), 120, 150, 200 joules (adult) preconfigured.
- Charge Time: Less than 10 seconds with a new fully charged battery. Depleted batteries will result in a longer defibrillator charge time.
- Energy Display: The monitor display indicates selected energy in manual mode only.
- AED Function: Auto analyze and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts.
- Electrodes: CPR-D padz, stat padz II, and Pediatric pedi padz II packaged in pairs. CPR-D padz one-piece electrode provides feedback on the rate and depth of chest compressions.
Display
- Screen Type: High-resolution LCD display.
- Screen Size: 3.02 inches W x 2.27 inches H.
- Sweep Speed: 25 mm/sec.
- Viewing Time: 3 seconds.
- Displayed Information: Heart rate, ECG waveform, text prompts, CPR bar graph, battery gauge, elapsed time, number of shocks delivered.
ECG Monitoring
- Patient Connection: 3-lead ECG cable.
- Input Selection: Fully defibrillator protected.
- ECG Size: Automatic Control (AUD) gain.
- Heart Rate: 30-300 bpm ±5%.
Battery
- Type: Rechargeable, sealed lead acid.
- Recharge Time: 4 hours or less with a ZOLL PowerCharger 4×4 or 1×1 Battery Charger.
- Operating Time: For a new, fully charged battery pack at 20º C: 170 defibrillator discharges at maximum energy, or 6 hours of continuous ECG monitoring.
- Type: Sealed, disposable lithium manganese.
- Operating Time: 300 defibrillator charges at maximum energy or 13 hours of continuous ECG monitoring.
Environmental
- Operating Temperature: 0º C to 50º C.
- Storage and Shipping Temperature: -30º C to 70º C.
- Humidity: 10% to 95% relative humidity, non-condensing.
- Vibration: MIL Std. 810F, Minimum Helicopter Test.
- Shock: IEC 68-2-27; 100G.
- Material/Water Ingress: IEC 60529, IP55.
- Electromagnetic Compatibility (EMC): CISPR; 11 Class B Rated and Conducted Emissions.
- Electromagnetic Immunity: AAMI DF-80; IEC 60601.
- Electrostatic Discharge: IEC 61000-4-2.
- Conducted Susceptibility: IEC 61000-4-6.